A review is given of the dielectric properties of various mammalian tissues and biological fluids for the frequency range from 1 Hz to 10 GHz. The properties considered are the frequency variations of the relative permittivity and electrical conductivity. An attempt has been made to present data which can be considered to be the most…
Clinical Physics and Physiological Measurement Template
Write in a clean editor, then format for Clinical Physics and Physiological Measurement in one click — DocuGuru applies the official IOP Publishing template with numbered references and exports a submission-ready PDF plus the editable LaTeX source. Free to start.
About the Clinical Physics and Physiological Measurement format
Clinical Physics and Physiological Measurement is a peer-reviewed journal published by IOP Publishing, covering Electrical and Bioimpedance Tomography, Hemodynamic Monitoring and Therapy, Body Composition Measurement Techniques.
| Publisher | IOP Publishing |
|---|---|
| Reference style | Numbered (IOP) Numbered — [1], [2] in the text [1] Smith A, Jones B and Lee C 2023 A representative article title Clinical Physics and Physiological Measurement 12 45–58
Formats any DOI in Clinical Physics and Physiological Measurement style. No sign-up. |
| Publishes research in | Electrical and Bioimpedance Tomography Hemodynamic Monitoring and Therapy Body Composition Measurement Techniques Geophysical and Geoelectrical Methods Non-Invasive Vital Sign Monitoring |
| ISSN | 0143-0815 |
| h-index | 59 |
| i10-index | 273 |
| Total citations | 12,738 |
| Top institutions publishing here | Royal Hallamshire Hospital |
| You get | A submission-ready PDF and the editable LaTeX source — ready to submit. |
Papers published in Clinical Physics and Physiological Measurement per year
Citation impact of Clinical Physics and Physiological Measurement by publication year
Citations each year’s papers have accumulated so far — the most recent years are still building up.
Most-cited papers in Clinical Physics and Physiological Measurement
Because of the intrinsically low sensitivity of any surface potential measurement to resistivity changes within a volume conductor, any data collection system for impedance imaging must be sensitive to changes in the peripheral potential profile of the order of 0.1%. For example, whilst the resistivity changes associated with lung ventilation and the movement of blood…
The lack of a reliable quantitative description of blood flow in man has hampered the development of accurate biokinetic models of essential elements, drugs, imaging agents, and carcinogens. In this paper we review and analyse data on blood flow and identify representative percentages of cardiac output and absolute blood flow rates to organs and tissues…
Applied potential tomography (APT) or electrical impedance imaging has received considerable attention during the past few years and some in vivo images have been produced. This paper reviews the current situation in terms of what in vivo results have been and are likely to be obtained in the near future. Both static and dynamic imaging…
The non-linear elastic response of arteries implies that their mechanical properties depend strongly on blood pressure. Thus, dynamic measurements of both the diameter and pressure curves over the whole cardiac cycle are necessary to characterise properly the elastic behaviour of an artery. We propose a novel method of estimating these mechanical properties based on the…